ES 95 Z

Particularités/options

  • Corps thermoplastique
  • Montage mural
  • Action lente: 2 contacts
  • Trous de fixation sur la longueur
  • Double isolation
  • Version pour porte et barriére disponible ES 95 WH/90° 1Ö/1S (inclus corde nylon lg 3.2 m et boule

Product image

 

Technical data

Standards IEC/EN 60947-5-1
Design DIN EN 50 047
Enclosure glass-fibre reinforced, shockproof
thermoplastic, self-extinguishing
UL 94-V0
Degree of protection IP 67 to IEC/EN 60529
Contact material silver
Switching elements change-over contact with double break, galvanically separated contact bridges
Switching system slow action, positive break
NC contacts Zwangsöffnung to IEC 60947-5-1
Connection screw terminals
Cable section max. 2.5 mm²
(incl. conductor ferrules)
Cable entry 1 x M 20 x 1.5
Uimp 4 kV
Ui 400 V
Ithe 6 A
Utilisation category AC-15; DC-13
Ie/Ue 6 A/400 VAC; 0.25 A/230 VDC
Max. fuse rating 6 A gL/gG D-fuse
Mech. life > 1 million operations
Switching frequency 1800/h
Ambient temperature – 20 °C … + 80 ºC
Contact opening 2 x 3.5 mm
Actuating force 20 N
Features pull-wire function
Approvals